PROJECT SERVICES · SVC-B

Flos specification support, measured at each gate

Architectural lighting moves from atmosphere to procurement through a sequence of technical decisions. Our service model organizes photometric review, luminaire coordination, controls interfaces and handover documents so architects, lighting designers, contractors and procurement teams can resolve the same brief without losing context. Inputs remain explicit: room geometry, finishes, target illuminance, mounting constraints, CCT, CRI, beam angle and protocol.

Structured project services

Each workstream produces a defined review package rather than an open-ended promise.

Optical selection

Review luminous flux, candela distribution, beam angle, shielding and visual comfort against room use. IES or LDT files support calculation where the selected family makes data available.

Fixture coordination

Check ceiling condition, trim or trimless detail, suspension length, access zone and finish schedule before release. Decorative products are coordinated with architectural systems rather than treated as isolated objects.

Driver and controls interface

Record DALI-2, 0–10V or phase-dimming intent, control zones, sensor locations and emergency requirements. Compatibility still depends on the final driver, controller and local wiring method.

Documentation handover

Assemble schedules, installation references and available certification records for contractor review. UL, CE and RoHS references apply only to documented products and markets.

A four-stage verification path

01 — Frame

Convert intent into criteria

Capture the visual task, architectural constraints, control expectations and decision dates. A hospitality lounge and a workplace task zone should not inherit identical glare, spectrum or scene logic.

02 — Model

Test photometric assumptions

Import documented photometry into the project model, check illuminance and uniformity, then inspect vertical brightness and likely sightlines. Calculation results remain dependent on geometry and reflectance inputs.

03 — Coordinate

Resolve physical interfaces

Align cut-outs, drivers, ceiling access, control addressing and circuit intent with the electrical and interior packages. Samples can be reviewed under representative finishes before approval.

04 — Handover

Close the information loop

Issue the selected schedule and commissioning assumptions. On site, aiming and scene tuning must be verified under actual furniture, surface and daylight conditions.

Application boundary: photometric simulations do not reproduce every adaptation response, surface variation or field tolerance. Wireless performance depends on building fabric; dimming behavior depends on the exact driver-load-controller combination; final compliance remains subject to project jurisdiction and product documentation.

Prepare a specification review

Send the lighting plan, room schedule and control basis for a focused response.